Initial Audit:
Re-Audit:
Lead-Auditor:
Additional Auditor:
A. Master Data
Location of Company Basic Data
Name of Company Year of foundation
Street Legal status
City Language spoken in company
Zip Code Total capacity per month
Country Contact Person
Phone Name
Fax Position / Language
http://www Phone
E-mail E-mail
Business Structure No. of customers? 6
No. of companies own units? 3 No. of subcontractors? 10 No. of suppliers, sub-suppliers? 4
A.1 Sales Revenue Export / Local Market
Share of sales revenue for export and local market during the last 3 years? Export Markets
Year 2001 2002 2003
Export/Local
Turn Over (US $)
A.2 Production Structure (inhouse) at the date of audit
Departments
No. of employees
Departments
No. of employees
How many shifts does the company run? 1
Day Middle Night
No. of employ
A.3 Employment Structure at the date of audit
Employees in total 314
Female employees 107 → Pregnant / maternity leave 2/2
Children below min. age of …16… years - → Apprentices -
Young employees aged …16… to 17 years 13 → Apprentices / trainees -
Wage Earners 314 Disabled persons 2
? On a monthly rate - Migrant workers 1
? On a daily rate - Employees on probation 10
? On a hourly rate - Handymen 20
? Piece raters - Home workers -
Assessment Minimum Social Requirements
Agreed to Declaration of Consent? Yes No
1. Audit Results
Results
Essentials
2 1 0 NA
B.1 Management Practice X
B.2 Documentation X
B.3 Working Time X
B.4 Compensation X Delay of Social Insurance application for 3 workers out of 314 and deducting 12 USD from wages of workers who loose their swipe cards.
B.5 Child Labour / Young Employees X
B.6 Forced Labour / Prison Labour X
B.7 Freedom of Association X
B.8 Discrimination X
B.9 Working Conditions X
B.10 Health and Social Facilities X
B.11 Occupational Health and Safety X PPE, emergency exit routes, lighting and exits,safety regulations and operating procedures for steam boilers.
B.12 Dormitories X
B.13 Environment X
Total Result: □Good □ Improvements Needed X Critical
2. Description of the Results
2.1 Negative points
ü 2 of the young workers have worked overtime after 20:00.
2.2 Positive points
ü The company provides free lunch and transportation.
ü The company gives food aid in religious festivals worth about 80 USD.
ü Half wage bonus is given twice a year.
ü Overtime payments are calculated over 220 hours instead of 225 hours.
ü The factory representatives were very eager to be audited as they believe it helps them to improve themselves.
2.3 Remarks
ü The company has implemented subcontractor procedures in February 2003.Therefore it could not be verified if the subcontractors continuously improve conditions to meet the social requirements.
ü As per document checks of 25 workers, one worker has been employed when she completed 13 years of lifetime in 1998.
2.4 Photos
餐廳
緊急出口被貨物堵塞
倉庫無出口瑩光燈
包裝車間總覽
暢通通道
燙衣部總覽
燙衣位的工作臺堵塞疏散
車縫位的工作臺堵塞疏散
醫(yī)療室
工廠入口處
逃生門開口向內開
電調節(jié)器前無橡皮墊
通通堵塞
貨物堆放高度大于3米
車縫部圖
Assessment "On Tops" for SA8000> Level
Results
Essentials
2 1 NA
C.1 Policy X Lack of policy for SA8000> requirements
C.2 Planning and Implementation X Lack of training records
C.3 Management Review X Lack of internal audits
C.4 Control of subcontractors /Suppliers / Sub-suppliers X Lack of procedures for suppliers and sub-suppliers.
C.5 Control of Homeworkers X
C.6 Compensation X Lack of basic need wage plan
C.7 Child Labour X Lack of documented remediation policy
C.8 Evasion X
C.9 Outside Communication X Lack of procedure to communicate
Ripe for SA8000> Certification with regard to audit results B. and C.: YES X NO
Training and assistance necessary but SA8000> certifiable YES X NO
2. Description of the Results
2.1 Positive Points:
2.2 Remarks:
|